The Open box printers sold hereare returned printers. Benjamin Moore Primer Reviews, Cinco Ranch Logo, Butcher Box Login, Yogi Tea Bedtime Ingredients, Hotels In Hollywood, Fl, Choczero Chocolate Chips Canada, No Time To Die Flute Notes, Divorce 070 Shake, Published by. Controlling and Managing the devices remotely or over local network. Quickly get Espressif's RF performance test tool, test firmware, test guide and certification test guide for ESP32, ESP32-C3, ESP32-S2, and ESP8266 series of product. fee is so expensvie and the seller didn't agree to afford the return Fortunately, Marlin 2.0.x does add the feature. Recv: T:26.34 /0 B:60.04 /60 T0:26.34 /0 T1:-20.Bibo 2 firmware 2 Taster mit (! Helps you to select layer height in a way, that Z axis moves only by full step increments. ![]() Recv: Info:Distortion correction matrix: Want to get some feedback before I go live with the updated version. If you guys don't mind doing some testing by installing the plugin using the url below in plugin manager that would be great. It should give you an idea of how your bed is leaning though for sure. The x/y positions on the surface are still just a division of the overall bed dimensions and not the actual x/y coordinates supplied by the reporting due to firmware differences. My tests with old marlin formats and newer repetier format seem to be working properly. Through the use of some multi-dimensional sorting and a final flip of the z positions I think it is reporting correctly now. I'm not really that familiar with numpy, so I'll be doing some searching. That way the input array will always be in the same format. I think the easiest approach to resolve this would be to apply a 2 dimensional sort on the array prior to processing. Old marlin report seems to go back and forth within the rows/column while repetier performs a diagonal move between each row/column. ]Īs mentioned it's completely because of the order in which the probe points are queried/reported. This is what is happening within the plugin. Ok, I've done some debugging with the virtual printer and faking the response from the 2 variations of firmware responses. Thanks for the great plugin and outstanding support you provide to all its users!! Should you need any additional data to be collected or tests to be run in case you update the code - I'm ready to assist. Would be nice to have more detailed description of this functionality in the documentation. If the plugin does not expect negative values, this may be causing problem.īeing new user of your plugin, I found it difficult to understand whether Flip options will just change the chart appearance, or affect the way printer output will be interpreted the next time G33 is run. In my printer offsets are: X_offset = -24.500, Y_offset = -13.5mm. ![]() Repetier calculates them as X value at measured point plus the X offset between probe and the nozzle. One other thing that may be unusual in my case - X coordinates (probe location) of few first measurement points are negative. Not sure if this matters, just decided to bring it to your attention. As I mentioned in my original post these movements are different. While the extract from serial.log in my previous post is result of executing G33 command, the order in which the lines with XYZ values appear in the printout follows the probe movement as for G32 command. G1 X100 S0 F6000 Move head back to bed center Step Why do you even need flip options? Aren't you parsing the actual X and Y values from the received distortion correction matrix? G1 Y100 F6000 Move head back to bed center Step 3a G1 X0 Y0 F4000 Move head to X0 Y0 Step 3c G1 X20 S0 F6000 Move head back to print area Step 3b G1 Y20 F6000 Move head back to print area Step 3a M190 S60 Wait for bed to reach temp before proceeding These are my GCODE commands from plugin settings: G28 This is the drawing with elevated Xmin/Ymin corner (correct): Running OctoPrint 1.3.10 on OctoPi 0.16.0. ![]() In my tests I used 3x3 grid (just to save time). Not sure if this is a bug, "feature" or something I need to change in the configuration. I am new to auto bed leveling and what caught my eye was that Repetier scans the grid differently when running G32 and G33 commands. ![]() Flip along Y worked, but in fact flipped the image along X. It just hanged showing "Please wait, retrieving current mesh" message. With selected Flip X option plugin failed to parse the output. Other 2 corners are swapped.įlipping along X and Y in this case won't really help, but I still tried. I was running tests with business card placed on top of one of the bed corners.Corners Xmin/Ymin and Xmax/Ymax appear at the right places. I am attaching 4 screenshots demonstrating the issue. It is up and running, but the bed is mirrored along the diagonal line from Xmin/Ymin to Xmax/Ymax. Hi, am trying to use Bed Visualizer Plugin with Repetier firmware 1.0.3.
0 Comments
Leave a Reply. |